Wiser Smoke Alarm LED behaviour guide. Follow

Pairing

User Action

LED Indication

Status

Press the Setup/Reset button 3 times

Status LED blinks amber, once per second.

Pairing mode is active for 30 seconds. When pairing is completed, status LED glows green for some time before turning Off.

Resetting

User Action

LED Indication

Status

Press the Setup/Reset button 3 times and hold it for > 10 s.

After 10 s, status LED starts blinking red.

The device is in reset mode. It is reset to the factory settings after 10 seconds. The device then restarts and the status LED starts blinking green before turning Off.

Operating

 

Operating Mode Standby LED Alarming Sound Duration

Normal mode / Standby mode

Blinks every 48s

OFF

—

Alarm Mode

Local Alarm *

Blinks every 1s

3 beeps every 4s

—

Interconnected alarm

OFF

3 beeps every 4s

—

Test mode

1 blink every 1s

3 beeps every 4s

Until Test/Hush button is released

Wireless interconnection test

OFF

Continuous 3 beeps every 4s

25s

Hush mode

Blinks every 8s

OFF

10min

Low battery mode

Blinks every 48s

1 beep every 48s

End of life: replace smoke alarm

Fault mode

2 blinks every 48s

2 beeps every 48s

Until fault has been cleared

Snooze Mode

Low battery

Blinks every 24s

OFF

10hrs

Fault

2 blinks every 24s

OFF

10hrs

Alarm memory

Blinks every 48s

OFF

10hrs

NOTE: For all the operating modes, LED blinks Red.

* For local smoke alarms, all red LEDs blink, whereas, for local temperature alarms, only the standby red LED blinks.

No LED

LED Indication Status
No LED

If the device is not displaying any LED behaviour this could indicate:

  1. The battery is depleted and needs to be replaced
  2. The device has failed and may need to be replaced*

*To determine if a replacement is required please raise a ticket with our technical support team. 

 
To view the full table please click here 
Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request
Return to top

Related articles

  • Wiser Temperature/Humidity Sensor LED behaviour guide
  • Wiser Radiator Thermostat LED behaviour guide

Wiser

Copyright © Drayton By Schneider Electric. All Rights Reserved.

English (United Kingdom) Deutsch