Wiser Smoke Alarm LED behaviour guide. Follow
Pairing
User Action |
LED Indication |
Status |
Press the Setup/Reset button 3 times |
Status LED blinks amber, once per second. |
Pairing mode is active for 30 seconds. When pairing is completed, status LED glows green for some time before turning Off. |
Resetting
User Action |
LED Indication |
Status |
Press the Setup/Reset button 3 times and hold it for > 10 s. |
After 10 s, status LED starts blinking red. |
The device is in reset mode. It is reset to the factory settings after 10 seconds. The device then restarts and the status LED starts blinking green before turning Off. |
Operating
| Operating Mode | Standby LED | Alarming Sound | Duration | |
|---|---|---|---|---|
Normal mode / Standby mode |
Blinks every 48s |
OFF |
— |
|
Alarm Mode |
Local Alarm * |
Blinks every 1s |
3 beeps every 4s |
— |
Interconnected alarm |
OFF |
3 beeps every 4s |
— |
|
Test mode |
1 blink every 1s |
3 beeps every 4s |
Until Test/Hush button is released |
|
Wireless interconnection test |
OFF |
Continuous 3 beeps every 4s |
25s |
|
Hush mode |
Blinks every 8s |
OFF |
10min |
|
Low battery mode |
Blinks every 48s |
1 beep every 48s |
End of life: replace smoke alarm |
|
Fault mode |
2 blinks every 48s |
2 beeps every 48s |
Until fault has been cleared |
|
Snooze Mode |
Low battery |
Blinks every 24s |
OFF |
10hrs |
Fault |
2 blinks every 24s |
OFF |
10hrs |
|
Alarm memory |
Blinks every 48s |
OFF |
10hrs |
|
NOTE: For all the operating modes, LED blinks Red. * For local smoke alarms, all red LEDs blink, whereas, for local temperature alarms, only the standby red LED blinks. | ||||
No LED
| LED Indication | Status |
| No LED |
If the device is not displaying any LED behaviour this could indicate:
*To determine if a replacement is required please raise a ticket with our technical support team. |